30V 3000A (90kW) high-frequency IGBT polarity reversing rectifier

Product Description:

The XTL GKDH30±3000CVC is a 30V 3000A (90kW) high-frequency IGBT polarity reversing rectifier for electroplating, electropolishing, and electrocoagulation applications.

Controlled by a Siemens PLC and HMI, this automatic polarity reversing DC power supply features independently adjustable forward/reverse times, configurable dead time, soft start, and CC/CV operation. It also supports RS485 communication for industrial automation integration.

Model & Data

Main Technical Specifications

Parameter Specification
Product Type Automatic Polarity Reversing Rectifier
Model / Rated Output 30V 3000A
Rated Output Voltage 30V DC
Rated Output Current 3000A
Rated Output Power 90kW
Control Technology High-Frequency IGBT
Control System PLC + HMI Touchscreen
Operating Mode Constant Current (CC) / Constant Voltage (CV)
Polarity Control Automatic Forward / Reverse Switching
Forward Time Setting Independently Adjustable, 0–999 Hours
Reverse Time Setting Independently Adjustable, 0–999 Hours
Dead Time Adjustable
Current Ramp Function Soft Start / Ramp-Up
Communication Interface RS485
Dimension 1150*553*1315mm
Weight 265KG

Key Features and Advantages

1

Automatic Polarity Reversal

Automatically switches between forward and reverse DC output according to preset schedules, eliminating manual polarity changes. Forward and reverse times are independently adjustable from 0 to 999 hours.

2

Adjustable Dead Time

Features configurable dead time between forward and reverse polarity switching, allowing the output current to stop during transition for controlled and stable operation.

3

Soft Start & Ramp Control

The adjustable soft-start function gradually increases output current, reducing sudden current impact and ensuring smoother operation during startup and polarity reversal.

Siemens PLC + HMI Intelligent Control

Equipped with Siemens PLC and a touchscreen HMI for easy configuration of polarity switching cycles, dead time, output voltage, and output current. Real-time operating data and alarm records are also available.

RS485 Communication

The RS485 interface supports communication with external PLCs and industrial control systems, enabling remote monitoring and integration into automated electrochemical production lines.

CC & CV Modes

Supports both constant current (CC) and constant voltage (CV) control, providing flexible output regulation for electroplating, electropolishing, and electrocoagulation processes.

Product Applications

Applications of GKDH30±3000CVC Polarity Reversing Rectifier

1

Electroplating

This 30V 3000A Polarity Reversing Rectifier is suitable for specialized reverse-polarity electroplating processes, including copper, nickel, chromium, zinc, gold and silver plating. Its programmable forward and reverse cycles provide flexible current direction control for electroplating applications. It can also serve as a Reverse Pulse Electroplating Rectifier for processes requiring periodic polarity reversal.

2

Electropolishing

As a Reverse Polarity DC Power Supply, the GKDH30±3000CVC supports metal surface treatment processes that require controlled polarity switching. It is suitable for specialized electropolishing applications involving stainless steel, precision components and other metal parts.

3

Electrocoagulation

This Electrocoagulation Power Supply is designed for wastewater treatment systems using aluminum or iron electrodes. Its automatic polarity reversal function helps reduce electrode passivation and buildup during operation, depending on process conditions. The programmable control system makes it suitable for industrial electrocoagulation applications.

Frequently Asked Questions (FAQ)

Q1: What is a polarity reversing rectifier?

A polarity reversing rectifier is a DC power supply that can automatically switch its positive and negative output terminals according to a preset schedule or control signal. It is commonly used in electroplating, electropolishing, electrocoagulation, and other electrochemical processes requiring alternating current direction.

Q2: What is the difference between a conventional DC rectifier and a polarity reversing rectifier?

A conventional DC rectifier normally maintains a fixed output polarity, while a polarity reversing rectifier can automatically switch between forward and reverse polarity. This allows users to control electrochemical processes requiring periodic changes in current direction.

Q3: Can the forward and reverse times be adjusted independently?

Yes. The XTL polarity reversing rectifier allows independent adjustment of forward and reverse operating durations. The standard adjustment range is 0–999 hours, and longer operating periods can be customized according to project requirements.

Q4: Can the dead time between polarity reversals be adjusted?

Yes. The dead time can be configured through the HMI touchscreen to provide an adjustable interruption interval between forward and reverse operation.

Q5: Does the rectifier support soft-start functionality?

Yes. The rectifier features a current ramp-up function that gradually increases the output current, helping reduce sudden current changes during startup and polarity switching.

Q6: Does the polarity reversing rectifier support constant current and constant voltage modes?

Yes. It supports both CC and CV operating modes, allowing users to select the appropriate control method for different electrochemical processes.

Q7: Can the rectifier communicate with an external PLC or computer?

Yes. The equipment is equipped with an RS485 communication interface for integration with external industrial control systems. Communication protocol and control details can be confirmed according to project requirements.

Q8: Can XTL customize polarity reversing rectifiers for different applications?

Yes. XTL can customize output voltage, current rating, forward/reverse timing, dead time, control functions, and other electrical or mechanical specifications according to specific application requirements.